Legionella risk assessment in Long Eaton

Updated 7 September 2026

Key points

  • Legionella risk assessments in Long Eaton are required for any non-domestic premises with a water system that can aerosolise water
  • Your mains water supplier is Severn Trent Water
  • Typical cost: £150 to £600, depending on the size and complexity of the water system
  • Use our cost calculator for a specific estimate

Long Eaton grew on lace manufacturing and later furniture-making, and its former mills and factory buildings now house flats, workshops, and small businesses with pipework that has typically been altered many times over. Dense terraced streets near the town centre are heavily rented to commuters working in Derby and Nottingham, keeping landlord risk assessments a large share of local work. The town sits close to the Trent and the Erewash, with marinas and riverside businesses nearby, and its schools, care homes, GP practices, salons, and leisure premises round out a compact assessment base.

Local water supply

The mains water supplier for Long Eaton is Severn Trent Water (Severn Trent Water website). The mains supply is treated and controlled by the supplier, so your legionella duties begin where the water enters your premises. Anything downstream of the boundary stop tap (storage tanks, calorifiers, pipework, outlets) is your responsibility.

Water in the Long Eaton area is classed as Hard on the Drinking Water Inspectorate hardness scale (around 258.9 mg/l as CaCO3), according to WaterGrade water quality data (single source - unverified). Harder water lays down scale inside calorifiers, cylinders, and mixing valves, and scale gives legionella a foothold while blunting temperature control, so in hard-water areas descaling and inspection belong in the written scheme of control. Check your supplier's postcode water-quality checker for the figure for your exact supply zone.

Legionnaires' disease in the East Midlands

The most recent regional surveillance figures recorded 58 confirmed cases of legionellosis in the East Midlands in 2023, a rate of 1.2 per 100,000 residents.

58Confirmed cases, East Midlands, 2023
1.2Rate per 100,000 residents

These are the confirmed figures UKHSA states explicitly; a full region-by-region table is not published, and surveillance counts only laboratory-confirmed, reported cases, so they are a floor rather than the true total. The national picture, with the trend since 2017, is on the Legionella Data Index. The regional figure changes nothing about your own duties: whatever the count, a non-domestic water system in Long Eaton still needs a risk assessment, a control scheme, and the records to show the scheme is being followed.

Typical cost in Long Eaton

Legionella risk assessment costs in Long Eaton depend more on the water system than on the location. A rough guide:

Cooling towers drive the cost up because they are notifiable to the local authority under the Notification of Cooling Towers and Evaporative Condensers Regulations 1992, and they need quarterly sampling and extensive cleaning. Get a tailored estimate with our cost calculator.

Free legionella risk assessment template

A structured Word document following the five-step approach in ACOP L8. Covers risk identification, written scheme, monitoring, and records. If it isn't written down, you can't evidence it.

Follows ACoP L8 and HSG274 Part 2. Free. No spam.

Legionella enforcement in the East Midlands

Prosecutions for legionella failings are usually brought under the Health and Safety at Work etc. Act 1974, whether by the HSE, a local authority, or (in Scotland) the Crown Office and Procurator Fiscal Service. No case in our tracker is recorded in Long Eaton itself; the cases below are the most recent recorded elsewhere in the East Midlands, shown as regional context rather than local history. They are drawn from our legionella enforcement tracker, which records each one against its primary source:

Amey Community Limited, 2024 (Facilities management) — fined £600k. Facilities manager at HMP Lincoln, where a 71-year-old prisoner died of Legionnaires' disease in 2017. The firm had failed to act on a 2016 risk assessment, had no written control scheme, and did not monitor water temperatures.

Four Seasons Health Care Limited, 2016 (Care home) — fined £600k. A 90-year-old resident died of Legionnaires' disease at a Kirkby-in-Ashfield care home in 2012 after the company failed to properly manage legionella in the water system. Prosecuted by the local authority.

The failings behind these cases are consistent: no suitable risk assessment, no written scheme of control, monitoring not carried out, or records that could not show the controls happened. The full dataset is on the enforcement tracker, and legionella fines and prosecutions explains how the courts approach sentencing.

Find a legionella risk assessor in Long Eaton

We are building a directory of qualified water hygiene assessors in Long Eaton and across the UK. In the meantime, look for assessors who:

Legionella testing labs covering Long Eaton

Routine temperature monitoring is done on site, but where your risk assessment or written scheme calls for water sampling, the samples go to a laboratory for culture. None of the UKAS-accredited laboratories in our directory is based in Long Eaton itself, so the nearest UKAS-accredited labs are listed below — all accept postal samples, and posted sampling is how most premises use them:

Methods, turnaround times and published prices for the full directory are compared on the legionella testing labs page. Sampling is not a substitute for day-to-day control: a clear result records what was found at that outlet on that day, it never certifies a system as safe, and it sits alongside the routine checks in your written scheme of control, not instead of them.

Building types in Long Eaton

Different building types have specific legionella considerations. Browse the guides most relevant to Long Eaton premises:

Related water hygiene products and services from trusted UK providers will appear here.

Free legionella risk assessment template

A structured Word document following the five-step approach in ACOP L8. Covers risk identification, written scheme, monitoring, and records. If it isn't written down, you can't evidence it.

Follows ACoP L8 and HSG274 Part 2. Free. No spam.

Important This page is general guidance only. Legionella risk varies with the specific water system, its use, and the people exposed to it. You should consult a competent legionella risk assessor for advice on your premises. LegionellaCheck is an independent information service and is not affiliated with HSE, UKAS, the Legionella Control Association, or any water hygiene company. This site does not provide medical advice. If you suspect Legionnaires' disease, contact NHS 111 or your GP.