Legionella risk assessment in Cambridge
Updated 7 September 2026
Key points
- Legionella risk assessments in Cambridge are required for any non-domestic premises with a water system that can aerosolise water
- Your mains water supplier is Cambridge Water
- Typical cost: £150 to £600, depending on the size and complexity of the water system
- Use our cost calculator for a specific estimate
Cambridge's legionella risk assessment demand is dominated by the university and its colleges, the Addenbrooke's and Royal Papworth hospital campus, and the biomedical and technology cluster around the Cambridge Biomedical Campus. College buildings present an unusual combination of medieval fabric, Victorian additions, and modern refurbishment, producing water system layouts that rarely match any standard template.
Local water supply
The mains water supplier for Cambridge is Cambridge Water (Cambridge Water website). The mains supply is treated and controlled by the supplier, so your legionella duties begin where the water enters your premises. Anything downstream of the boundary stop tap (storage tanks, calorifiers, pipework, outlets) is your responsibility.
Water in the Cambridge area is classed as Very hard on the Drinking Water Inspectorate hardness scale (around 301-310 mg/l as CaCO3), according to MyTapWater water quality data (two agreeing sources - unverified). Harder water lays down scale inside calorifiers, cylinders, and mixing valves, and scale gives legionella a foothold while blunting temperature control, so in hard-water areas descaling and inspection belong in the written scheme of control. Check your supplier's postcode water-quality checker for the figure for your exact supply zone.
Legionnaires' disease: the national picture
UKHSA does not publish a separate surveillance figure for the East of England, so no regional number is shown here. The most recent national figure recorded 472 confirmed cases of legionellosis across England and Wales in 2024 — the England & Wales average context, not a count for this region.
UKHSA states figures explicitly for only a handful of regions; a full region-by-region table is not published, and surveillance counts only laboratory-confirmed, reported cases, so the national total is a floor rather than the true number of infections. The full picture, with the trend since 2017, is on the Legionella Data Index. The absence of a regional figure changes nothing about your own duties: a non-domestic water system in Cambridge still needs a risk assessment, a control scheme, and the records to show the scheme is being followed.
Typical cost in Cambridge
Legionella risk assessment costs in Cambridge depend more on the water system than on the location. A rough guide:
- Small premises, mains-fed only, no storage: £150 to £250
- Typical office or shop with a hot water cylinder: £200 to £400
- Care home, hotel, or school with stored hot and cold water: £400 to £800
- Premises with a cooling tower or evaporative condenser: from £800, often much higher
Cooling towers drive the cost up because they are notifiable to the local authority under the Notification of Cooling Towers and Evaporative Condensers Regulations 1992, and they need quarterly sampling and extensive cleaning. Get a tailored estimate with our cost calculator.
Free legionella risk assessment template
A structured Word document following the five-step approach in ACOP L8. Covers risk identification, written scheme, monitoring, and records. If it isn't written down, you can't evidence it.
Follows ACoP L8 and HSG274 Part 2. Free. No spam.
Legionella enforcement in the East of England
Prosecutions for legionella failings are usually brought under the Health and Safety at Work etc. Act 1974, whether by the HSE, a local authority, or (in Scotland) the Crown Office and Procurator Fiscal Service. No case in our tracker is recorded in Cambridge itself; the cases below are the most recent recorded elsewhere in the East of England, shown as regional context rather than local history. They are drawn from our legionella enforcement tracker, which records each one against its primary source:
Bupa Care Homes (BNH) Limited, 2018 (Care home) — fined £1.5m. An 86-year-old resident died of Legionnaires' disease at a Brentwood care home in 2015, months after refurbishment. The company failed to flush and disinfect the system, the manager lacked training, warnings were ignored and records were falsified. Fined £3m, reduced to £1.5m by the Court of Appeal.
Tendring District Council, 2018 (Local authority leisure) — fined £27k. A member of the public contracted Legionnaires' disease from the water system at the council-run Walton-on-the-Naze leisure centre. HSE found inadequate risk assessments, insufficient staff training and a lack of monitoring across several council leisure sites. Fined £27,000 plus £7,197 costs and a £170 victim surcharge at Colchester Magistrates' Court in December 2018.
The failings behind these cases are consistent: no suitable risk assessment, no written scheme of control, monitoring not carried out, or records that could not show the controls happened. The full dataset is on the enforcement tracker, and legionella fines and prosecutions explains how the courts approach sentencing.
Find a legionella risk assessor in Cambridge
We are building a directory of qualified water hygiene assessors in Cambridge and across the UK. In the meantime, look for assessors who:
- Work for a company registered with the Legionella Control Association (the LCA is the main UK trade body for water hygiene)
- Hold a City & Guilds or equivalent qualification in legionella risk assessment
- Can provide references from similar premises in the Cambridge area
- Will quote against a clear scope (number of outlets, inclusion of hot and cold surveys, whether sampling is included)
Legionella testing labs covering Cambridge
Routine temperature monitoring is done on site, but where your risk assessment or written scheme calls for water sampling, the samples go to a laboratory for culture. None of the UKAS-accredited laboratories in our directory is based in Cambridge itself, so the nearest UKAS-accredited labs are listed below — all accept postal samples, and posted sampling is how most premises use them:
- Feedwater Laboratories (UKAS no. 2234), turnaround ~10 days, from £82.68 per sample
- Eurofins Water Hygiene Testing UK Limited (UKAS no. 9658)
- ALS Environmental (ALS Laboratories (UK) Limited) (UKAS no. 1314)
Methods, turnaround times and published prices for the full directory are compared on the legionella testing labs page. Sampling is not a substitute for day-to-day control: a clear result records what was found at that outlet on that day, it never certifies a system as safe, and it sits alongside the routine checks in your written scheme of control, not instead of them.
Building types in Cambridge
Different building types have specific legionella considerations. Browse the guides most relevant to Cambridge premises:
- Landlords and rental properties
- Offices
- Care homes
- Hotels
- Schools
- Dental practices
- All building types
Related water hygiene products and services from trusted UK providers will appear here.
Free legionella risk assessment template
A structured Word document following the five-step approach in ACOP L8. Covers risk identification, written scheme, monitoring, and records. If it isn't written down, you can't evidence it.
Follows ACoP L8 and HSG274 Part 2. Free. No spam.