What is legionella monitoring?
On this page
Key points
- Monitoring is the repeating loop of measure, record, act and review that sits under the written scheme of control. It is not a one-off test.
- A typical regime mixes frequencies: weekly flushing, monthly sentinel temperatures, quarterly shower head cleaning, six-monthly tank inspection, annual calorifier checks and a full review.
- Monitoring is thermometers, not laboratories for most systems. Sampling is a separate activity triggered by the risk assessment.
- Every check needs four things: a named outlet or asset, a target, a result, and a written record. An unrecorded check cannot be evidenced.
- Records are kept for at least five years under ACOP L8. The log book is where the whole regime lives.
Legionella monitoring is the set of routine checks that shows your water system's controls are still working: temperatures taken at chosen outlets, little-used outlets flushed, shower heads cleaned, tanks and calorifiers inspected, and every result written down. It runs on a calendar of different frequencies, from weekly flushing to an annual review, and it is the part of legionella management that never stops. The risk assessment is a snapshot; monitoring is the film.
This page is the hub for the monitoring cluster. It explains what a monitoring regime is, what it watches, and how the pieces fit together, and it points to the detailed guides on each part: the monitoring schedule, sentinel outlets, weekly checks, annual checks, and the monitoring log sheet.
What a monitoring regime actually is
Under ACOP L8, a duty holder must appoint a competent person, assess the risk, prepare a written scheme of control, and then implement, manage and monitor that scheme. Monitoring is the last link in that chain. It is how you know the scheme is real and not just a document in a drawer. The regime is built from four ingredients:
- Tasks. The specific checks: take this temperature, flush that outlet, inspect this tank. Each one exists because the risk assessment found something it controls.
- Frequencies. How often each task runs. HSG274 Part 2 gives the usual starting points, and the risk assessment adjusts them for your building.
- Targets. What a good result looks like: hot at 50°C or more within a minute (55°C in healthcare), cold below 20°C within two minutes, calorifier storage at 60°C or above. The temperature chart sets out the numbers.
- Records. The written log of every check and every action. Keep them at least five years.
The four things every regime watches
Whatever the building, a monitoring regime is watching the same four conditions, because they are the four things legionella needs:
- Temperature. Water between about 20°C and 45°C is the growth range. Monitoring confirms hot stays hot and cold stays cold. See temperature control.
- Movement. Stagnant water is where legionella establishes. Flushing records show little-used outlets are turned over before they stagnate. See flushing little-used outlets.
- Cleanliness and condition. Scale, sediment and biofilm shelter and feed the bacteria. Inspection and cleaning records show tanks, calorifiers, shower heads and thermostatic mixing valves are being kept in a condition that does not harbour growth.
- The record itself. The log book is evidence the other three are being watched. A regime with no records is indistinguishable from no regime at all.
The monitoring loop: measure, compare, act, review
A working regime is a loop, not a list. Each check follows the same cycle: measure something, compare it against the target, act if it is out of range, and record all three steps. When a sentinel outlet will not reach 50°C, the loop does not end at writing down the number. It continues into finding out why, whether that is a failing thermostatic mixing valve, a calorifier set too low, or a circulation problem, and recording what was done. How you monitor legionella walks through the task stack in detail.
Once a year the loop widens into a full review: are the controls still the right ones, has the building or its use changed, and does the risk assessment need revisiting. That is the subject of the annual checks.
Monitoring is the difference between having a written scheme and having a working one. The record of each check is the only thing that proves the controls ran.
Free legionella risk assessment template
A structured Word document following the five-step approach in ACOP L8. Covers risk identification, written scheme, monitoring, and records. If it isn't written down, you can't evidence it.
Follows ACoP L8 and HSG274 Part 2. Free. No spam.
Monitoring is not testing
The most common confusion in this area is between monitoring and sampling. For a typical hot and cold water system controlled by temperature, routine monitoring means thermometers, log sheets and physical inspections, not laboratory bottles. Sampling is a separate, targeted activity: the risk assessment may call for it, a system that cannot hold temperature may need it, and any positive result changes what the regime has to do next. Sampling and action levels explains when testing applies and what the results mean.
Where the regime lives: the log book
Everything the regime produces, temperatures, flushes, inspections, cleaning, actions, lands in one place: the log book. A simple bound book or folder works for a small premises; a digital log makes missed checks easier to spot. Our legionella log book tool lets you record each check as you do it, and the temperature monitoring template gives you a printable sheet for the monthly round. If you are starting from scratch, the risk assessment builder helps you work out which checks your system actually needs, and the temperature checker tells you whether a reading you have taken is in range.
The regime a monitoring programme serves is set by the written scheme of control, which in turn comes from the risk assessment. Monitoring is the daily and weekly reality of that chain of documents. It does not certify a system as safe, and no log book ever can. What it does is produce the continuous, dated evidence that the controls you chose were carried out, and that when they failed, someone noticed and acted.
Free legionella risk assessment template
A structured Word document following the five-step approach in ACOP L8. Covers risk identification, written scheme, monitoring, and records. If it isn't written down, you can't evidence it.
Follows ACoP L8 and HSG274 Part 2. Free. No spam.
Frequently asked questions
What is legionella monitoring?
Legionella monitoring is the programme of routine checks that shows your control measures are still working between risk assessments. It covers temperature checks at sentinel outlets, flushing of little-used outlets, cleaning of shower heads and spray fittings, and inspections of tanks and calorifiers, with every result written down. It is not a one-off test: it is the repeating loop of measure, record, act and review that sits underneath the written scheme of control.
Is legionella monitoring a legal requirement?
There is no clause that names monitoring as a standalone duty, but it follows directly from the legal framework. The Health and Safety at Work Act 1974 and COSHH require you to control the risk, and ACOP L8 requires a written scheme of control that is implemented and properly managed. A scheme that is never checked or recorded is not being implemented, so in practice routine monitoring with records is the only way to show the duty is being met.
What is the difference between legionella monitoring and testing?
Monitoring is the routine in-house checking of the things that keep legionella in check: temperatures, flushing, cleaning and physical condition. Testing, or sampling, means sending water to a laboratory to culture the bacteria. Most hot and cold water systems rely on temperature control, so their routine monitoring is about thermometers, not laboratories. Sampling is added where the risk assessment calls for it, where temperatures cannot be held in range, or where the control regime depends on a chemical treatment.
Who should carry out legionella monitoring?
The responsible person named under ACOP L8 owns the monitoring regime, but individual checks can be delegated to anyone who is competent for the task: a caretaker, site manager or trained member of staff. Whoever does the check needs to know what to measure, what the target is, what to do when a reading is out of range, and how to record it. The duty holder remains accountable for the whole regime.
How long should legionella monitoring records be kept?
ACOP L8 expects records to be kept for at least five years. That covers temperature logs, flushing records, inspection reports, cleaning records and any remedial actions taken. Five years of consistent records is what lets you show an inspector, insurer or court not just that controls exist on paper, but that they have been carried out continuously.